A weakness has been identified in Tenda F451 1.0.0.7_cn_svn7958. This issue affects the function fromSetIpBind of the file /goform/SetIpBind. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks.
A critical stack-based buffer overflow vulnerability exists in Tenda F451 router firmware (version 1.0.0.7_cn_svn7958) affecting the SetIpBind function. The vulnerability allows remote attackers to execute arbitrary code by manipulating the 'page' parameter, with no patch currently available. This poses significant risk to Saudi organizations relying on Tenda routers for network infrastructure.
IMMEDIATE ACTIONS:
1. Identify all Tenda F451 devices in your network using network scanning tools (Nmap, Shodan queries for Tenda devices)
2. Isolate affected routers from critical network segments if possible
3. Restrict remote access to router management interfaces (disable WAN-side access to port 80/443)
4. Monitor for exploitation attempts targeting /goform/SetIpBind endpoint
COMPENSATING CONTROLS:
1. Implement network segmentation to limit router access to trusted administrative networks only
2. Deploy WAF/IPS rules to block requests with suspicious 'page' parameter values to SetIpBind function
3. Change default credentials and disable remote management features
4. Monitor router logs for unusual SetIpBind function calls
5. Consider replacing Tenda F451 with alternative vendors (Cisco, Juniper, Fortinet) that receive regular security updates
DETECTION RULES:
1. Monitor HTTP POST requests to /goform/SetIpBind with oversized 'page' parameter values
2. Alert on any SetIpBind requests originating from external networks
3. Track firmware version of all Tenda devices; flag version 1.0.0.7_cn_svn7958
4. Monitor for unexpected process execution or system crashes on router devices
الإجراءات الفورية:
1. تحديد جميع أجهزة Tenda F451 في شبكتك باستخدام أدوات المسح (Nmap، استعلامات Shodan)
2. عزل الأجهزة المتأثرة عن القطاعات الحرجة إن أمكن
3. تقييد الوصول البعيد إلى واجهات إدارة الجهاز (تعطيل الوصول من جانب WAN)
4. مراقبة محاولات الاستغلال التي تستهدف نقطة نهاية /goform/SetIpBind
الضوابط التعويضية:
1. تطبيق تقسيم الشبكة لتحديد وصول الجهاز للشبكات الإدارية الموثوقة فقط
2. نشر قواعد WAF/IPS لحجب الطلبات ذات قيم معاملات 'page' المريبة
3. تغيير بيانات الاعتماد الافتراضية وتعطيل ميزات الإدارة البعيدة
4. مراقبة سجلات الجهاز للاتصالات غير العادية
5. النظر في استبدال Tenda F451 بموردين بدائل يتلقون تحديثات أمان منتظمة
قواعد الكشف:
1. مراقبة طلبات HTTP POST إلى /goform/SetIpBind بقيم معاملات 'page' كبيرة
2. تنبيه على أي طلبات SetIpBind من شبكات خارجية
3. تتبع إصدار البرنامج الثابت لجميع أجهزة Tenda
4. مراقبة تنفيذ العمليات غير المتوقعة على الأجهزة